Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Interv Neuroradiol ; : 15910199241245156, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38576332

ABSTRACT

PURPOSE: Pulsatile tinnitus can be caused by a high-riding jugular bulb (HRJB), characterized by the superior position of the jugular bulb in the petrous temporal bone. The anatomical position and morphology of this entity make it challenging for endovascular treatment. We report our experience with two patients successfully treated with a stent-assisted Woven EndoBridge (WEB; Microvention, Tustin, CA, USA) device. MATERIALS AND METHODS: We describe two cases of HRJB in patients presenting with disabling pulsatile tinnitus. Temporary balloon occlusion of the jugular bulb prior to the intervention reduced tinnitus intensity. Both patients were subsequently treated under general anesthesia with the WEB device deployed in the HRJB which was held by a stent deployed in the sigmoid sinus. RESULTS: Both procedures were successful with good positioning of the WEB device and no procedural complications. Both patients had complete resolution of pulsatile tinnitus immediately after the procedure. Follow-up imaging showed successful occlusion of the venous cavity with a widely patent stent. CONCLUSION: Among patients with pulsatile tinnitus caused by an ipsilateral HRJB, a stent-assisted WEB device seems to be a viable endovascular option with angiographic and clinical success.

2.
Interv Neuroradiol ; : 15910199241240504, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38529582

ABSTRACT

The Woven EndoBridge (WEB) is an intra-aneurysmal flow disruptor designed for the treatment of broad-based arterial aneurysms with a high safety and effectiveness profile.1, 2 It does not require concomitant antiplatelet therapy compared to other devices such as flow diverters or intracranial stents. Innominate artery pseudoaneurysms are a rare consequence of blunt traumatic injury, infection, or atherosclerotic disease.3, 4 We describe the case of an innominate artery pseudoaneurysm successfully treated with a WEB SL device instead of stenting, therefore alleviating the need for dual antiplatelet therapy. The treatment was successful and uneventful and postprocedural computed tomography angiography confirmed the complete occlusion of the pseudoaneurysm.

4.
J Neurointerv Surg ; 2023 Oct 30.
Article in English | MEDLINE | ID: mdl-37903560

ABSTRACT

Tandem occlusions, characterized by the simultaneous presence of an intracranial large vessel occlusion and extracranial carotid artery stenosis or occlusion,1 pose a unique endovascular challenge.2 3 Typically, the extracranial occlusion is a result of atherosclerotic plaque; however, dissections are also a possible cause. It is currently uncertain whether an intracranial first approach or an extracranial first approach should be employed.4 5 A new technique has been developed which allows for the simultaneous treatment of both the intracranial and the extracranial lesion.6 We describe a variation of this technique: the stent retriever for tandem acute revascularization technique (START), which consists of simultaneously treating the intracranial lesion with stent retriever and contact aspiration, and the extracranial lesion with balloon angioplasty. We present a technical video explaining all the steps of START.(video 1)neurintsurg;jnis-2023-021011v1/V1F1V1Video 1Description and example of the START.

5.
J Neurointerv Surg ; 2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37875343

ABSTRACT

Pulsatile tinnitus is a symptom with a potentially significant impact on the quality of life of patients.1 In some cases the pulsatile tinnitus is secondary to an arterial, arteriovenous, or a venous condition that can be treated endovascularly.2-5 One of the newly recognized entities that can cause pulsatile tinnitus is the presence of an ipsilateral aneurysmal diverticulum of the transverse sinus. The Woven EndoBridge (WEB) is an intra-aneurysmal flow disruptor for the treatment of broad-based arterial aneurysms with a high safety and effectiveness profile.3 The initial version of the WEB with a dual-layer structure evolved into a single-layer structure in two different versions (WEB SL, a barrel shape, and WEB SLS, a spherical shape).4 The WEB system does not require concomitant antiplatelet therapy, unlike other intraluminal devices such as flow diverters or intracranial stents. We describe a case of pulsatile tinnitus secondary to an aneurysmal diverticulum of the transverse sinus successfully treated with a WEB SL device instead of stent-assisted coiling, therefore alleviating the need for antiplatelets (video 1). The patient had an immediate clinical response with complete and persisting disappearance of her pulsatile tinnitus.neurintsurg;jnis-2023-020981v1/V1F1V1Video 1.

6.
J Neuroradiol ; 50(6): 600, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37699501

ABSTRACT

Detachable-tip microcatheters are frequently used for endovascular embolization of arteriovenous shunts. Occasionally, the detachable tip can break during navigation resulting in the loss of the microcatheter tip in a vessel, which can lead to thrombo-embolic complications and also limit further navigation into the vessel to complete treatment. We present a case of dural AV-fistula embolization that was complicated by the accidental detachment and loss of the tip of a microcatheter during navigation to injection site. The proximal tip of the broken catheter was not visible and therefore we were unable to capture its proximal part with a Snare. Ultimately, we navigated a microcatheter distal to the broken segment and successfully snared the microcatheter fragment retrogradely. (Video 1).


Subject(s)
Embolization, Therapeutic , Humans , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/methods , Catheters/adverse effects , Catheterization , Microsurgery , Equipment Design
SELECTION OF CITATIONS
SEARCH DETAIL
...